DMU-03

DMG MORI DMU 50 (3rd Generation) · Siemens SINUMERIK ONE · Bay 1 · Cell C · s/n DMU50-24099

Live machine view
Five-axis cycle
X/Y/Z, the swivelling B trunnion and the C rotary table follow live telemetry; the door opens when the machine stops. Drag to rotate, scroll to zoom.
Idle
Effectiveness
OEE this shift
Night (22:00–06:00) · 364 of 398 min running
72%

Availability

91.5%

Performance

79.5%

Quality

98.7%

Current job
WO-24114
Bracket, actuator · AD-3310-A

Pieces

40 / 40

Cycle time

4m 56s

This piece

0s elapsed

Operator

Arden Adams

Tool

T7 · Ø6 finishing end mill

Tool life left

43%

Finishes

—

Losses
Downtime by reason
33.9 minutes lost this shift, biggest first.

Setup / first-off

13.2 min

Tool change

7.2 min

No material

4.7 min

Waiting QA

4.5 min

No operator

2.1 min

Breakdown

2.1 min

Quality
Pieces this shift
Ideal 228 s versus actual 287 s per piece.

Good

75

Scrap

1

Rework

0

OEE per hour · %

Queue
Jobs on this machine (3)
The job on the spindle and everything queued behind it, earliest due date first.

WO-24114

High

Helvetica Medtech · AD-3310-A OP10 · Al 7075-T6 · setup 112 min

Late

40/40 · due 26 Oct 00:37

WO-24115

Aerodyn Systems · NT-6650-A OP20 · Inconel 718 · setup 55 min

Queued

0/40 · due 27 Oct 19:37

WO-24116

Sandvik Tooling · ST-3390-A OP30 · H13 tool steel · setup 96 min

Queued

0/24 · due 28 Oct 14:37

Readings
Live telemetry
Polled every 5 seconds · spindle 18,506 h, service in 343 h

Spindle load

0 %

Spindle speed

0 rpm

Feed rate

0 mm/min

Spindle temp

20.7 °C

Coolant temp

20.1 °C

Coolant pressure

0 bar

Vibration

0 mm/s

Axis load B

0 %

Axis positions

X

0.0

Y

0.0

Z

0.0

B

0.0

C

0.0

Spindle history
Spindle load, speed and vibration

Spindle load · %

Spindle speed · rpm

Vibration · mm/s

Alarms
Alarms (8)

Door interlock opened during cycle

Alarm 6621 · 10-26 03:25

High

B axis drive temperature high

Alarm 1105 · 10-26 02:34

Medium

Tool life expired on T7, change required

Alarm 2019 · 10-26 02:13

Low

B axis drive temperature high

Alarm 1105 · 10-25 08:43

Medium

Tool life expired on T7, change required

Alarm 2019 · 10-25 02:38

High

Coolant level low in the tank

Alarm 7014 · 10-24 13:03

High

Coolant level low in the tank

Alarm 7014 · 10-24 12:16

High

Coolant level low in the tank

Alarm 7014 · 10-24 08:21

High